Mentalix Application Note #10009
Product: Pixel!FX
Software Version(s): 3.x, 4.x, 5.x
Platform(s): IBM
Subject: RS6000 using the second SCSI bus
Revision Date: April 21, 1995
Problem:
Pixel!SCAN is not seeing the scanner on SCSI bus 1, 2 or
3.
Solution:
-
Upgrade to v4.0-002 or later or 5.0-005 or later.
-
Run the Setup program.
-
Install the scanner as usual, but choose 'Create install script
-- don't execute'.
-
Exit Setup and edit the file /tmp/Mentalix_Install_Script.
-
Change the line:
/usr/sbin/mkdev -c scanner -s scsi -t scanjet -p scsi0 -w0....
TO
/usr/sbin/mkdev -c scanner -s scsi -t scanjet -p scsi1 -w0....
-
Replace -p scsi1 with the name of your SCSI controller device.
-
Execute the script /tmp/Mentalix_Install_Script.
For additional information or assistance, please call Mentalix
Technical Support at (972) 423-9377 Ext. 33.
|